TM 9-2320-366-20-3
Change 1
2-2230.3
PRESSURE TEST
(1)
Position drain pan under air/hydraulic
manifold
(2)
Disconnect hydraulic hose 513 from
PILOT port.
(3)
Connect STE/ICE-R between hydraulic
hose 513 and PILOT port.
(4)
Start engine (TM 9-2320-366-10-1).
(5)
Position SUSPENSION knob to LOWER
(TM 9-2320-366-10-1).
(6)
Position FUNCTION SELECT knob
to SUSPENSION (TM 9-2320-366-10-1).
(7)
Push and hold PUMP plunger button
(TM 9-2320-366-10-1) and perform
STE/ICE-R Test #51.
(8)
If 2,500-4,000 psi (17,238-27,580 kPa) is
not present, go to step 6 of this fault.
(9)
If 2,500-4,000 psi (17,238-27,580 kPa) is
present, repair or replace air/hydraulic
manifold (para 19-4).
(10)
Disconnect STE/ICE-R from hydraulic hose
513 and PILOT port.
(11)
Connect hydraulic hose 513 to PILOT port.