TM-9-2320-366-20-3

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 3 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-3 - Page 511 of 1396

TM 9-2320-366-20-3
c. Follow-On Maintenance.
(1) Lower cab (TM 9-2320-366-10-1).
(2) Start engine (TM 9-2320-366-10-1).
(3) Check for coolant leaks under vehicle.
(4) Add coolant to radiator overflow tank (TM 9-2320-366-
10-2).
(5) Check coolant level after normal operating temperature
is reached.
(6) Check for coolant leaks under vehicle.
(7) Raise cab (TM 9-2320-366-10-1).
(8) Check around thermostat housing for coolant leaks.
(9) Lower cab (TM 9-2320-366-10-1).
(10) Shut down engine (TM 9-2320-366-10-1).
End of Task.
3-5


Back to Top