TM 9-2320-366-20-4
b. Installation.
(1) Install WTEC III TPSS (1) in instrument panel assembly
(2).
(2) Position two brackets (3) and self-locking nuts (4) on
WTEC III TPSS (1).
(3) Tighten two self-locking nuts (4) to 11-13 lb-in. (1-2
N·m).
(4) Connect connector PX33 (5) to WTEC III TPSS
connector (6).
c. Calibration.
(1) Install instrument panel assembly (para 7-15).
NOTE
WTEC III TPSS requires calibration after
replacement. Calibration is accomplished in
steps (1.1) through (4).
(1.1) Position master power switch to on and wait for neutral
(N) indication from WTEC III TPSS (TM 9-2320-366-10-
1).
(2) Position master power switch to off (TM 9-2320-366-10-
1).
(3) Perform steps (1) and (2) four more times.
(4) Position master power switch to on (TM 9-2320-366-10-
1).
(5) Start engine (TM 9-2320-366-10-1).
(6) Check volts gage for charge indication (TM 9-2320-366-
10-1).
Change 1
8-7