CAUTION
Secure all wiring with tie wraps to prevent
contact with fan switch coils.
Failure to
comply may result in damage to equipment.
(38) Position DEFR control cable (19) on control plate (45).
(39) Install locking nut (55) on DEFR control cable (19).
(40) Position VENT control cable (25) on control plate (45).
(41) Install locking nut (56) on VENT control cable (25).
(42) Position HEAT control cable (57) on control plate (45).
(43) Install locking nut (58) on HEAT control cable (57).
(44) Position clamp (59) on hose (60).
(45) Connect hose (60) to valve (61).
(46) Tighten clamp (59) to 35-45 lb-in. (4-5 N·m).
(47) Position hose (60) and valve (61) in personnel heater
(2).
Change 1