TM-9-2320-366-20-5

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 5 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-5 - Page 274 of 1158

TM 9-2320-366-20-5
18-58
Change 2
18-9.
PERSONNEL HEATER REPLACEMENT/REPAIR (CONT)
(19) Position clamp (23) on heater outlet hose (2).
(20) Position clamp (23) on heater inlet hose (3).
(21) Position heater outlet hose (2) on return fitting
(27).
(22) Position heater inlet hose (3) on supply fitting
(28).
(23) Engage as many clamp tabs (25) as possible in
tab windows (26) allowing little or no play between
clamps (23) and heater outlet hose (2) and heater
inlet hose (3).
(24) Tighten two clamps (23) to 8-9 lb-in. (0.9-1 N•m).
(25) Measure gap between ends of two clamps (23).
CAUTION
Ensure clamp tongue is started in clamp
groove.
Failure to comply may result in
damage to equipment.
NOTE
Heater outlet hose is marked with an
arrow pointing down.
NOTE
Heater inlet hose is marked with an arrow
pointing up.
NOTE
Minimum allowable gap between ends
of clamp is 0.1 in. (0.3 cm).
If gap is
less than 0.1 in. (0.3 cm), remove and
re-install clamp.


Back to Top