Change 1
2-197
TM 9-2320-366-34-1
CONTINUITY TEST
CAUTION
Use care when disconnecting internal wiring
harness connectors. Failure to comply may
result in damage to equipment.
(1)
Remove control valve module (para 7-10).
(2)
Remove four screws and cover from
control valve module.
(3)
Disconnect internal wiring harness
connector A from A solenoid.
(4)
Set multimeter to ohms.
(5)
Connect positive (+) probe of multimeter
to internal wiring harness 24-pin connector
pin A1.
(6)
Connect negative (-) probe of multimeter to
internal wiring harness connector A pin A
and note reading on multimeter.
(7)
If continuity is not present, replace
transmission internal wiring harness
(para 7-13).
(8)
Connect positive (+) probe of multimeter
to internal wiring harness 24-pin connector
pin A1.
(9)
Connect negative (-) probe of multimeter
to all other pins in internal wiring harness
24-pin connector, except pins A2, D1, and
H1, and note reading on multimeter.
(10)
Connect negative (-) probe of multimeter
to ground and note reading on multimeter.
(11)
If continuity is present, transmission
internal wiring harness is shorted; replace
transmission internal wiring harness
(para 7-13).