Change 1
2-295
TM 9-2320-366-34-1
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter
to adapter cable 31-pin connector pin A.
(3)
Connect negative (-) probe of multimeter to
adapter cable 24-pin connector pin A2 and
note reading on multimeter.
(4)
If continuity is not present, replace
transmission adapter cable assembly
(para 6-8).
(5)
Connect positive (+) probe of multimeter
to adapter cable 31-pin connector pin A.
(6)
Connect negative (-) probe of multimeter to
all other pins in adapter cable 31-pin
connector and note reading on multimeter.
(7)
Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(8)
If continuity is present, transmission adapter
cable assembly is shorted; replace
transmission adapter cable assembly
(para 6-8).
(9)
Connect adapter cable 31-pin connector to
external wiring harness 31-pin connector.