TM 9-2320-366-34-3
16-63. 30K WINCH ASSEMBLY REPLACEMENT/REPAIR (CONT)
NOTE
• Left and right side lamp brackets are installed
the same way. Left side shown.
• Refer to
Table 16-2. Clearance Marker Light
Connector
for combinations of terminal lugs
and connectors on each marker light.
(19) Route harness (26) through 30K winch assembly (2).
(20) Install lamp bracket (27) on 30K winch assembly (2) with
three screws (28) and self-locking nuts (29).
(21) Connect harness connector (30) to electrical connector
489 (31).
(22) Install terminal lug (32) on marker light (33) with washer
(34) and nut (35).
(23) Perform steps (21) and (22) on right side lamp bracket.
Table 16-2. Clearance Marker Light Connectors
Marker Light Location
Connector
Terminal Lug
Left Side
P94
TL88
Right Side
P95
TL89
(24) Position monoblock valve (36) on 30K winch assembly
(2) with mounting plate (37), two screws (38), and self-
locking nuts (39).
(25) Position three screws (40) and self-locking nuts (41) in
mounting plate (37).
(26) Tighten three self-locking nuts (39 and 41) to 76-84 lb-ft
(103-114 N·m).
16-372