TM 9-22320-366-34-3
Change 2
16-483
(6)
Disconnect hydraulic hose (17) from flowmeter
valve assembly (18).
(7)
Remove flowmeter valve assembly (18) from
hydraulic tube (19).
(8) Remove adapters (20 and 21) from flowmeter
valve assembly (18).
(9)
Remove preformed packings (21.1) from
adapters (20 and 21).
Discard preformed
packings.
b.
Installation.
(1)
Position preformed packings (1.1) on adapters (1 and
2).
(2)
Position adapters (1 and 2) on flowmeter valve
assembly (3).
(2.1) Tighten adapters (1 and 2) to 22-24 lb-ft (30-33
N•m).
(3) Connect flowmeter valve assembly (3) to hydraulic
tube (4).
(4)
Connect hydraulic hose (5) to flowmeter valve
assembly (3).