TM-9-2320-386-10

2-1/2-TON, 6X6, M44A3 SERIES TRUCKS (DIESEL)

TECHNICAL MANUAL; EXTENDED SERVICE PROGRAM (ESP); OPERATOR’S MANUAL

JANUARY 1996

  TM-9-2320-386-10 - Page 83 of 223

TM 9-2320-386-10
2-50
2-12. STARTING THE ENGINE (ABOVE +20°F) (-6.7°C) (Contd)
CAUTION
Do not engauge starter switch for more than 15 seconds at any
time or with headlights on. If engine does not start in 15 seconds,
wait 30 seconds before engaging starter switch again. Failure to
do this may result in damage to starter.
i.
Engage starter switch (1) until engine starts.
CAUTION
If any instrument reading is not normal, stop engine immediately
by turning the accessory/battery switch to OFF position and notify
unit maintenance. Failure to do this may result in damage to
engine.
NOTE
The use of the ether quick-start system may be required for
temperatures below 32°F (0°C).
j.
Check for the following instrument readings:
(1)
Ensure oil pressure gauge (3) reads at least 35 psi (241 kPa).
(2)
Ensure battery/generator indicator (4) reads in the green area.
(3)
Drive vehicle 3-5 miles (5-8 km) prior to activating CTIS (2). ECU
should be turned to the OFF position if CTIS is not needed or if the
truck will be idled for an extended period.
1
2
3
4


Back to Top