TM 9-2320-386-24-1-1
0025 00
0025 00-7
ITEM
NO.
INTERVAL
ITEM TO
CHECK/
SERVICE
EQUIPMENT NOT
READY/AVAILABLE
IF:
PROCEDURE
Table 1. Unit Preventive Maintenance Checks and Services (Contd).
NOTE
Open hood and secure with holddown
catch (TM 9-2320-386-10).
a.
Inspect radiator (2) for clogged or bent
a.
Radiator is
fins (3) and protruding objects. Clean
clogged, bent, or
radiator (2) and straighten bent fins (3).
damaged.
b.
Test coolant freeze point.
c.
Inspect radiator for corrosion. If exces-
sive corrosion is found, flush radiator (2).
Flush radiator (2) and cylinder block every
four years (WP 0068 00).
d.
Inspect radiator mounts for cracks,
d.
Radiator mount(s)
breaks, or loose condition. If loose, tighten.
is cracked, broken,
If cracked or broken, replace (WP 0069 00). or loose.
15
Semiannually
Cooling
system
~
14
Semiannually
Body
a.
Remove heavy deposits of mud, rust,
gravel, etc. from body sheet metal panels
and frame rails. Use scraper and/or wire
brush, if necessary.
b.
Thoroughly wash all underbody sheet
metal panels and corners.
c.
Inspect for loose rivets, cracks, loose or
missing mounting hardware, and general
body damage.
2