TM-9-2320-387-24-1

TRUCK, UTILITY: S250 SHELTER CARRIER, 4X4, M1113

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE, VOLUME 1

DECEMBER 1997
CHANGE 1

  TM-9-2320-387-24-1 - Page 234 of 1205

TM
9-2320-387-24-l
REFERENCE ItjFORMATlON
ENGINE COOLING
FAN =PERATlJRE
SWITCH
1
2
1:
c
1:
RESISTANCE
AND CONTINUITY
04,500
OHMS
STEilCE-R TEST 91
1. Connect RED clip and BLACK clip to the
teminations
indicated in the question. RED to
the first, BLACK to the second.
2. Start Test 91,0-4.500
Ohms.
3. Displayed reading is in ohms.
Less than 5
ohms is continuity.
If the resistance is over
4,500 ohms, STEXE-R
displays
.9.9.9.9.
Repair/replace
wires (para. 4-90).
CONTINUITY (RESISTANCE)
MULTIMETER
.
Set the voltmeter to an ohms scale of about
1,000 ohms.
!. Connect the RED and BLACK leads to the
connections
stated in the question.
). Be sure to read the correct scale. Less than
5 ohms indicates continuity.
For an open circ
the meter should peg full scale (needle all the
way to the left).
Repair/replace
wires (para. 4-80).
DC VOLTAGE O-45 VOLTS
STUICE-R
TEST 89 ’
1. Connect RED clip to the indicated test
point, BLACK clip to negative or ground.
2. Start Test 89. DC Volts.
3. Displayed
reading is in volts.
Repair/replace
wires (para. 4-80).
VOLTAGE
MULTIMETER
1.
Set the voltmeter to a DC volts scale of at
least 40 volts.
2. Connect the RED lead to positive and the
BLACK lead to negative.
3. Be sure to read the correct scale.
. VALVE
2-177


Back to Top