TM-9-2320-387-24-1

TRUCK, UTILITY: S250 SHELTER CARRIER, 4X4, M1113

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE, VOLUME 1

DECEMBER 1997
CHANGE 1

  TM-9-2320-387-24-1 - Page 760 of 1205

TM 9-2320-387-24-l
i
4-16.
ELECTRICAL GAUGE
REPLACEMENT
I
This task covers:
a. Removal
INITIAL SETUP:
b. Installation
Tools
General mechanic’s
tool kit:
automotive (Appendix
B, Item 1)
Maintenance and repair shop equipment:
automotive (Appendix B, Item 21
Materials/Parts
Manual References
TM 9-2320-387-10
TM 9-2320-387-24P
Equipment Condition
Battery ground cables disconnected (para. 4-681.
Two lockwashers (Appendix G, Item 208)
Maintenance
Level
Unit
NOTE
l
Replacement procedures for all electrical gauges are basically
the same. This procedure covers the temperature gauge.
l
Prior to removal, tag all leads for installation.
-1
1.
Remove four screws (9) and washers (8) from instrument cluster (11 and instrument panel (61.
2.
Pull instrument cluster (1) away from panel (6).
3.
Disconnect leads (4) and (5) from gauge (10).
4.
Remove two
nuts (3), lockwashers (71, retaining bracket (21, and gauge (101 from instrument cluster (I).
Discard lockwashers (7).
1.
Install gauge (10) and retaining bracket (2) on instrument cluster (11 with two lockwashers (7) and
nuts (3). Tighten nuts (3) to 8 lb-in. (1 Nom).
2.
Connect leads (4) and (5) to gauge (10).
3.
Install instrument cluster (1) on panel (6) with four washers (8) and screws (9).
4-34


Back to Top