TM-9-2320-387-24-2

TRUCK, UTILITY: S250 SHELTER CARRIER, 4X4, M1113

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE, VOLUME 2

DECEMBER 1997
CHANGE 1

  TM-9-2320-387-24-2 - Page 1251 of 1555

TM 9-2320-387-24-2
33-22
Change 1
33-11. LEFT FRONT FLOOR PANEL REPAIR (Cont’d)
3.
Cut metal strip (2) from sheet metal, and mark two reference lines (1), centerline (3), directional
arrow (4), and letter B on metal strip (2).
4.
Locate, mark, and drill twenty-six 0.187-in. (4.75-mm) diameter holes through metal strip B (2).
5.
Cut two metal strips (5) from sheet metal, and mark centerlines (7), directional arrows (6), and
letters C and D on metal strips (5).
6.
Locate, mark, and drill seven 0.187-in. (4.75-mm) diameter holes through metal strip C (5).
7.
Locate, mark, and drill fourteen 0.187-in. (4.75-mm) diameter holes through metal strip D (5).
METRIC CONVERSION
0.60 IN.
15.24 MM
0.75 IN.
19.05 MM
1.25 IN.
31.75 MM
1.40 IN.
35.56 MM
1.85 IN.
46.99 MM
2.00 IN.
50.80 MM
2.125 IN.
53.98 MM
3.00 IN.
76.20 MM
5.40 IN.
137.16 MM
6.00 IN.
152.40 MM
35.50 IN.
901.70 MM
DRILL TWENTY-SIX 0.187-IN. (4.75-MM) DIAMETER HOLES
1.40


Back to Top