Table 1.
PMCS- SEMIANNUAL - Continued
Item
No.
Interval
Item to
be
Checked
or
Serviced
Procedure
Equipment
Not Ready/
Available If:
•
Use the proper lubricant
to purge all four bearing
seals of each universal
joint. This flushes
abrasive contaminants
from each bearing and
assures all four bearings
are filled properly. Pop
the seals, these seals are
made to be popped.
•
If any seals fail to purge,
move propeller shaft from
side-to-side while
applying gun pressure.
This allows greater
clearance on thrust end of
bearing that is not
purging. If seals still do
not purge, rock vehicle by
releasing the parking
brake, start engine, put
transmission in D (drive)
or R (reverse), and allow
vehicle to roll. This
removes the windup in
the drive line and allows
for a greater clearance on
the thrust end of the
universal joint.
•
Because of the design of
the universal joint seal,
there will occasionally be
one or more bearing
seals of a joint that may
not purge. If this occurs,
notify field level
maintenance.
TM 9-2320-435-10
0152
0152-4