GROUND ROD DRIVER DOES NOT OPERATE (CONTINUED)
THAAD0653
Step 19.
Connect pressure gage and hose to test port TP1. Start engine (
Position LHS cab control mode switch to MRP position (WP 0010). Check for 2,000 psi
(13,790 kPa) at test port TP1, when ground rod driver controls are operated (WP 0010).
If 2,000 psi (13,790 kPa) is measured at test port TP1, ground rod driver may
be faulty. Notify Supervisor.
THAAD0652
Step 20.
Remove safety wire from solenoid HV5. Soldier A checks for 2,000 psi (13,790 kPa) at
test port TP1, while HV5 bypass valve is pulled out and turned, and Soldier B operates
ground rod driver controls (WP 0010). Shut off engine (
Disconnect
pressure gage and hose.
If 2,000 psi (13,790 kPa) is not measured, install safety wire on solenoid HV5
and replace MRP control valve (WP 0138).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION