TM 9-2320-440-13&P
0135-4
0135
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
WARNING
The THAAD hydraulic system operates at oil pressure up to 3,250 psi (22,409 kPa).
Never disconnect any hydraulic line or fitting without first dropping pressure to
zero. Failure to comply may result in serious injury or death to personnel.
NOTE
•
Position drain pan under hydraulic lines and fittings being removed.
•
Tag and mark hydraulic lines prior to removal to ensure proper installation.
•
Cap and plug hydraulic lines upon removal.
•
Remove cable ties as required.
•
All four tubes are removed the same way.
Right side shown.
11. Remove hose 2882 (10) and hose 2892 (11) from two fittings (12).
12. Remove screw (13), lockwasher (14), cover plate (15), and two-piece clamp (16) from main frame (4).
13. Remove two screws (17), lockwashers (18), washers (19), cover plates (20), and two-piece clamps (21) from
main frame (4). Discard lockwasher.
THAAD0257