OPERATOR MAINTENANCE
FRAME RESTS ON SPRING BUMPER
INITIAL SETUP:
References
WP
0002
Equipment Condition
Trailer coupled to prime mover (WP
0005)
TROUBLESHOOTING PROCEDURE
SYMPTOM
FRAME RESTS ON SPRING BUMPER
MALFUNCTION
TRAILER IS OVERLOADED
CORRECTIVE ACTION
1.
Reduce load to proper payload (WP
0002).
2.
Verify problem is solved.
END OF WORK PACKAGE
TM 9-2330-202-13&P
0013
0013-1/2 blank