TM 9-2330-330-14&P
0126 00-3/4blank
FUEL SAMPLING VALVE REMOVAL
1.
Disconnect hose (4) from fuel sampling valve (3).
2.
Remove fuel sampling valve (3) from top of filter separator (1).
3.
Plug opening in top of filter separator (1) with plug from cap and plug set.
FUEL SAMPLING VALVE INSTALLATION
1.
Remove plug from opening in top of filter separator (1).
NOTE
Apply thread sealing compound to threads of valve.
2.
Install fuel sampling valve (3) in top of filter separator (1).
3.
Connect hose (4) to fuel sampling valve (3).
FOLLOW-ON TASKS
1.
Reconnect negative battery terminal (WP 0007 00).
2.
Disconnect semitrailer grounding cables (WP 0007 00).
END OF TASK