TM 9-2330-330-14&P
0007 00-20
c.
Remove one or both vapor recovery system caps.
d.
Start engine (para. G). When engine is warm, adjust to idle speed (1000–1200 rpm).
e.
Remove 4-in. hose (3) from hose tube (2) and connect hose (3) between outlet B (5)
and fuel storage facility.
f.
Pull emergency valve A control handle (7) to open position. Open valves B, F, and
H (4, 5, and 6).
g.
Adjust engine speed to desired flow rate (290–320 gpm [1098–1211 Lpm] @ 2200–2400 rpm).
h.
Shut off engine after delivery is complete.
i.
Close all valves and vapor recovery system vent caps.
j.
Drain hose (2) into suitable container.
k.
Remove and store hose (2) in hose tube (3).
l.
Remove grounding and bonding cables.
m. Store and cover fire extinguisher (1).
OPERATION UNDER USUAL CONDITIONS—Continued
0007 00