TM 9-2330-334-13&P
AIR SYSTEM LOSES PRESSURE DURING
OPERATION/SLOW AIR PRESSURE BUILDUP
0042 00
AIR SYSTEM TROUBLESHOOTING - Continued
Table 1.
Air System Loses Pressure During Operation/Slow Air Pressure Buildup - Continued.
0042 00-11/12-Blank
Change 1
INDICATION/CONDITION
DECISION (NO/YES)
PROCEDURAL STEPS
11.
Does air hose 301 have any
kinks, leaks or holes?
No
Replace ABS ECU valve
(WP 0071 00).
1.
Apply soapy water solution
to air hose 301 and fittings.
Yes
Replace air hose 301.
2.
Check air hose 301 between
ABS ECU valve and air tank
for bubbles indicating holes
or leaks.
3.
Check fittings for bubbles
indicating leaks.
END OF WORK PACKAGE