TM 9-2330-334-13&P
AIR SYSTEM LOSES PRESSURE DURING
OPERATION/SLOW AIR PRESSURE BUILDUP
0042 00
AIR SYSTEM TROUBLESHOOTING - Continued
Table 1.
Air System Loses Pressure During Operation/Slow Air Pressure Buildup.
Change 1
0042 00-2
INDICATION/CONDITION
DECISION (NO/YES)
PROCEDURAL STEPS
1.
Is air tank drain valve open
or leaking?
No
Go to (Indication/Condition
2).
1.
Ensure air tank drain valve is
closed.
Yes
Replace air tank drain valve
(WP 0078 00).
2.
Feel for air escaping from air
tank drain valve.