TM 9-2330-334-13&P
SUSPENSION SYSTEM SITS UNEVEN-Continued
0045 00
PNEUMATIC SYSTEM TROUBLESHOOTING - Continued
Table 1.
Uneven Suspension System - Continued.
Change 1
0045 00-4
INDICATION/CONDITION
DECISION (NO/YES)
PROCEDURAL STEPS
4.
Does brake protection valve
operate properly? (Cont)
No.
Replace brake protection
valve (WP 0075 00).
4.
Disconnect air hose from tee
fitting.
Yes.
Go to (Indication/Condition
5).
5.
Begin pressurizing air
system and note if brake
protection valve opens at
70-75 psi. indicating proper
operation.
6.
Drain air tank and note if
brake protection valve
closes at 60-65 psi.
indicating proper operation.
7.
Connect air hose to tee
fitting.
8.
Remove pressure gage and
pipe bushing from air tank.
9.
Install ½ inch plug in air
tank.
5.
Does height control valve
operate properly?
No.
Replace height control
valve (WP 0084 00).
1.
Check height control valve
for proper installation and
operation (WP 0084 00).
Yes.
Properly adjust linkage (WP
0084 00).
END OF WORK PACKAGE