TM 9-2330-334-13&P
ANTI-LOCK BRAKE SYSTEM (ABS) POWER AND DIAGNOSTIC
0074 00
CABLE AND DIAGNOSTIC TOOL REPLACEMENT - Continued
0074 00-13
Change 1
INSTALLATION – Continued
NOTE
Install plastic cable ties as required.
12.
Route two hoses (14) and main electrical harness (12) through LH frame rail (19).
13.
Position two hoses (14) and main electrical harness (12) into two clamps (18).
14.
Position two clamps (18) on LH frame rail (19) with two bolts (17) and self-locking nuts (16).
15.
Tighten two self-locking nuts (16) to 96-120 lb-in. (11-14 N·m).