TM 9-2330-334-13&P
AIR TANK REPLACEMENT-Continued
0078 00
0078 00-5
Change 1
INSTALLATION-Continued
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off
harmful vapors, and are harmful to skin and clothing. To avoid injury or
death, keep away from open fire and use in a well-ventilated area. If
adhesive, solvent, or sealing compound gets on skin or clothing, wash
immediately with soap and water. Failure to comply may result in injury
to personnel.
3.
Apply sealing compound to threads of fitting (7) and drain valve (6).
4.
Install fitting (7) in air tank (3).
5.
Install drain valve (6) in air tank (3).
6.
Install air tank (3) on brackets (5) with two clamps (4).