TM 9-2330-334-13&P
BREATHER VALVE REPLACEMENT - Continued
0082 00
0082 00-4
REMOVAL - Continued
NOTE
Tag hoses and connection points prior to disconnecting.
4.
Disconnect hoses (8 and 9) from adapter (10) and 90-degree fitting (11).
5.
Remove adapter (10) and 90-degree fitting (11) from tee fitting (12).
6.
Remove breather valve (13) from tee fitting (12).