TM 9-2330-334-13&P
DRAWBAR LIFT VALVE REPLACEMENT - Continued
0094 00
Change 1
0094 00-4
INSTALLATION
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off
harmful vapors, and are harmful to skin and clothing. Keep away from open
fire and use in well-ventilated area. If adhesive, solvent, or sealing compound
gets on skin or clothing, wash immediately with soap and water. Failure to
comply may result in injury to personnel.
1.
Apply sealing compound to threads of two plugs (9), fitting (4), and two 90-degree fittings (2).
2.
Position drawbar lift valve (7) in vise.
3.
Install two 90-degree fittings (2) on drawbar lift valve (7).
4.
Install fitting (4) on drawbar lift valve (7).
5.
Install two plugs (9) on drawbar lift valve (7).