1. Remove spout from overwing nozzle.
TM 9-2330-356-14
2. Install quick disconnect converter.
Figure 2-44. Installing Converter Onto Overwing Nozzle.
2-19.
Refuel on the Move (ROM) Assembly and
Operating Procedures (M969 and M969A1)
(Fig. 2-45)
WARNING
Fuel handlers must wear appropriate safety
equipment during fueling operations to avoid
injury.
NOTE
Components of the Refuel Assembly Kit
(NSN 4730-01-295-1842) are listed In
Appendix D.
a.
Select refuel site and park fuel tank semitrailer at
right side of road.
b.
Open Refuel on the Move (ROM) accessory
container. Unpack instruction sheets and inventory sheet.
Take inventoy of components of container.
c.
Unload the three 4-inch hoses from hose troughs.
Remove dust cap from valve B and the three hoses.
Connect the three hoses together and attach one end to
valve B.
NOTE
The number of fueling points to be connected
and operated may vary. Additional hose
sections of the type provided in the kit maybe
connected to the basic ROM system for
additional reach if needed to satisfy special
deployment conditions.
d.
Lay out ROM parts on ground per Instruction
Drawing 12356089.
NOTE
Apply teflon tape to all male coupling threads.
Reapply as needed during subsequent de-
ployments to ensure proper seal of connec-
tions.
e.
Attach parts, starting with large 4-inch tee, to the
4-inch hose from the fuel tank semitrailer. If equipped,
open valve on tee assemblies before operating.
f.
Remove dust caps and assemble parts. Ensure
that camlock clamps hold parts together tightly.
g.
Place fire extinguishers at refuel sites (8). Place a
ground rod at each refuel site and pound 18 inches into
ground with slide hammer on ground rod.
h.
Place nozzles on ground rod handle.
2-51