TM-9-2350-238-20-1

HULL AND RELATED COMPONENTS RECOVERY VEHICLE, FULL TRACKED: LIGHT, ARMORED, M578

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL

MAY 1994

  TM-9-2350-238-20-1 - Page 116 of 1364

TM 9-2350-238-20-1
2-11. TROUBLESHOOTING INFORMATION (CONT).
Table 2-3. UNIT TROUBLESHOOTING (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
110. PERSONNEL HEATER DOES NOT OPERATE AND PERSONNEL HEATER CONTROL
BOX LIGHT IS ON.
Step 1.
Check fabric fuel cell fuel level.
Fill fabric fuel cell. Refer to TM 9-2350-238-10.
Step 2.
Check personnel heater ground lead for bad connection.
Clean ground connections with crocus cloth (item 10, appx C). Tighten
ground connection.
Step 3.
Troubleshoot personnel heater circuit. Refer to Electrical Circuit Symptom
Index, page 2-92.
FIXED FIRE EXTINGUISHER
111. SYSTEM DOES NOT DISCHARGE.
Step 1.
Check weight of fire extinguisher.
If needed, charge fire extinguisher, Refer to page 2-13.
Step 2.
Check C02 cylinder control valve.
2-90


Back to Top