TM 9-2350-238-20-1
Step 2.
Place red probe on battery post
(4).
Place black probe on battery post (5).
If multimeter indicates less than about 24 volts, replace cable (6). Refer to
page 2-640. If multimeter indicates about 24 volts, go to step 3.
Step 3.
Disconnect cable (7) from battery post (1). Place red probe on battery
post (1). Ground black probe. If multimeter indicates less than about 24
volts, replace cable (8). Refer to page 2-640. If multimeter indicates
about 24 volts, go to step 4. Connect cable (7) to battery post (1 ).
2-95