TM 9-2350-238-20-1
Make sure MASTER switch is OFF before repairing
electrical circuits. Failure to observe this warning
could result in injury to personnel.
Step 7.
Disconnect GND lead from windshield defroster disconnect. Place red
probe in GND lead. Ground black probe. Set MASTER switch ON. Set
windshield defroster switch ON. If multimeter indicates about 24 volts, go to
step 8. If multimeter indicates no voltage, repair GND lead between
windshield defroster and windshield defroster disconnect. Refer to page
2-371. If multimeter still indicates no voltage, replace windshield. Refer to
page 2-1073. Set MASTER switch OFF. Set windshield defroster switch
OFF. Connect lead.
2-353