TM 9-2350-238-20-2
NOT E
Tag all leads for identification .
5
Disconnect two electrical leads (11) from two electric floodlights (12 and 13) .
6
Disconnect foodlamp to ground electrical lead (14) from electric floodlight (13) .
7
Remove two hexagon plain nuts (15), two Iockwashes (16), and two packing gland sprin g
tension washers (17) from two electric floodlights (12 and 13) .
8
Remove two electric floodlights (12 and 13) .
9
Loosen three screws (18) .
2-28 1