TM 9-2350-238-20- 2
2 9
3 0
3 1
3 2
3 3
Disconnect electrical leads (42) from rec-
tifier (43) .
Remove two machine screws (44), tw o
flat washers (45), two level wind rec -
tifier mounting brackets (46), and rec -
tifier (43) from level wind rectifier sup-
port bracket (47) .
Remove two hexagon capscrews (48) ,
two lockwashers (49), and level win d
rectifier support bracket (47) .
Refer to page 2-66 for complet e
disassembly of electrical leads (42) .
If damaged, remove three marker band s
(50) from electrical leads (42) .
INSPECTION/REPAI R
1
Inspect for broken, damaged, or missing parts .
2
Marker bands are manufactured items, refer to appendix D .
3
Repair is by replacement of authorized parts (TM 9-2350-238-24P-2) .
INSTALLATIO N
1
If necessary, install three new marke r
bands (1) on electrical leads (2) .
2
Refer to page 2-66 for complete reas -
sembly of electrical leads (2) .
3
Install level wind rectifier support bracke t
(3) and secure with two new lockwash -
ers (4) and two hexagon capscrews (5) .
4
Install two level wind rectifier mountin g
brackets (6) and rectifier (7) on leve l
wind rectifier support bracket (3) and
secure with two flat washers (8) and
two machine screws (9) .
5
Connect three electrical leads (2) to rec-
tifier (7) .
2-28 5