2-10. ELECTRICAL CIRCUIT TROUBLESHOOTING (CONT) .
Step 2.
Remove both leads 518 (1) from circuit breaker (2). Connect multimeter t o
receptacles of circuit breaker. If multimeter indicates continuity, go to ste p
3. If multimeter indicates infinity, replace circuit breaker, refer to pag e
2-297. Connect leads .
Make sure MASTER switch is OFF before repairing electrical com-
ponents. Failure to observe this warning could result in injury t o
personnel .
Step 3.
Disconnect lead 518 (1) from FLOODLIGHTS switch (2) input. Place re d
probe in lead 518. Ground black probe. Set MASTER switch ON. I f
multimeter indicates about 24 volts, go to step 4. If multimeter indicates n o
voltage, repair lead 518 between FLOODLIGHTS switch and circuit breaker ,
refer to page 2-66. Set MASTER switch OFF. Connect lead .