TM 9-2350-238-20- 2
Step 4 .
Disconnect both leads 518 (1) from FLOODLIGHTS switch (2). Connec t
multimeter to FLOODLIGHTS switch. Set FLOODLIGHTS switch ON. I f
multimeter indicates continuity, repair lead 518 between floodlights an d
FLOODLIGHTS switch, refer to page 2-66. If multimeter indicates infinity ,
repair FLOODLIGHTS switch, refer to page 2-297. Set FLOODLIGHT S
switch OFF. Connect leads .
2-5 3