TM-9-2350-256-10

RECOVERY VEHICLE, FULL TRACKED: MEDIUM, M88A1

OPERATOR'S MANUAL

OCTOBER 2014

  TM-9-2350-256-10 - Page 697 of 796

SERVICING APU AIR CLEANER - Continued
8.
Set filter element (Figure 2, Item 4) aside in a dust free area to dry or circulate heater air at no more than
150°F (65°C).
9.
Wipe the inside of the air filter housing cover (Figure 2, Item 7) with a clean, damp cloth.
NOTE
Before putting filter element back, inspect it for tears or holes. If any are found, notify
maintenance to replace filter element.
10.
Install filter element (Figure 2, Item 4) and plate (Figure 2, Item 3) in filter housing (Figure 2, Item 6), and
install wingnut (Figure 2, Item 1) with gasket (Figure 2, Item 2). Hand tighten wingnut.
11.
Install housing cover (Figure 2, Item 7) on filter housing (Figure 2, Item 6) and secure with two filter housing
clips (Figure 2, Item 5).
Figure 2.
APU Air Cleaner.
END OF TASK
END OF WORK PACKAGE
TM 9-2350-256-10
0120
0120-3/blank