OPERATOR MAINTENANCE
SMOKE GRENADE LAUNCHER SYSTEM MAINTENANCE
INITIAL SETUP:
Tools and Special Tools
General mechanic's tool kit
(WP 0135, Table 1, Item 2)
Materials/Parts
General purpose detergent Qty: AR
(WP 0134, Table 1, Item 9)
General purpose lubricating oil Qty: AR
(WP 0134, Table 1, Item 45)
Materials/Parts (cont.)
Nonelectrical wire Qty: AR
(WP 0134, Table 1, Item 79)
Wiping rags Qty: AR (WP 0134, Table 1, Item 57)
References
FM 3-34.214 (WP 0131)
TM 9-1300-200 (WP 0131)
CLEANING
WARNING
Before performing any maintenance on smoke grenade launcher system, visually confirm
that no smoke grenades are in launcher tubes. If grenades are found, remove grenades
from dischargers and return them to metal ammunition storage boxes. Failure to comply
may result in personnel death or injury.
NOTE
Refer to TM 9-1300-200 (WP 0131) and FM 3-34.214 (WP 0131) for destruction
instructions for grenade launcher.
Do not use wire brush to clean barrels of dischargers.
1.
Clear debris from discharger barrels.
2.
See that drain holes in barrels are clear by inserting a stiff wire.
3.
Clean barrels with general purpose detergent and water, as applicable.
4.
Wipe with a clean, dry cloth. Be sure that no residue remains around the tip plugs, which are located at the
bottom center of each barrel.
5.
Apply general purpose lubricating oil lightly to pins in each barrel.
6.
Install canvas covers to protect discharger barrels from dust, grit, and debris.
END OF TASK
END OF WORK PACKAGE