TM-9-2350-256-10

RECOVERY VEHICLE, FULL TRACKED: MEDIUM, M88A1

OPERATOR'S MANUAL

OCTOBER 2014

  TM-9-2350-256-10 - Page 709 of 796

OPERATOR MAINTENANCE
ACETYLENE CYLINDER REPLACEMENT, IF EQUIPPED
INITIAL SETUP:
Tools and Special Tools
General mechanic's tool kit
(WP 0135, Table 1, Item 2)
Materials/Parts
Acetylene cylinder (WP 0132, Table 1, Item 1)
General purpose detergent Qty: AR
(WP 0134, Table 1, Item 9)
Spray bottle (WP 0134, Table 1, Item 5)
Personnel Required
Crewman (3)
References
Acetylene/oxygen torch setup (WP 0053)
TC 9-237 (WP 0131)
WARNING
Acetylene gas is stored under extremely high pressure. Ensure acetylene cylinder
is properly stowed and connected. Ensure protective cap is in place when cylinder
is not in use. Damage to cylinder or leaking lines could cause an explosion. Failure
to comply may result in personnel death, injury, and/or damage to equipment.
Ensure acetylene cylinder valve is turned off before removing regulator valve.
Acetylene is under high pressure. Failure to comply may result in personnel death,
injury, and/or damage to equipment.
TM 9-2350-256-10
0125
0125-1