TM-9-2350-256-20-2

RECOVERY VEHICLE, FULL TRACKED: MEDIUM, M88A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL VOLUME 2 OF 2

JUNE 2005

  TM-9-2350-256-20-2 - Page 379 of 1440

TM 9-2350-256-20-2
0228 00
Assembly
1.
Assemble wiring harness (see WP 0255 00 thru 0264 00, as appropriate).
Installation
1.
Connect two connectors (7 and 8) to switch panel to neutral safety to bulkhead wiring harness (22).
2.
Connect connector (6) to bulkhead disconnect (18) using gasket (21), four lockwashers (20), and four screws (19).
3.
Connect connector (5) to rigger’s light selector switch (17).
4.
Connect connector (4) to gage panel to bulkhead wiring harness (16).
5.
Connect connector (3) to switch panel to gage panel and miscellaneous switches wiring harness (passive night viewer)
(dual voltage) (15).
6.
Install 19 clamps (12) using lockwasher (14) and screw (13) for each.
7.
Connect lead (2) using lockwasher (11) and screw (10).
8.
Connect connector (1) to APU control box (9).
NOTE
Follow-on maintenance: Install air cleaner (see WP 0137 00).
END OF WORK PACKAGE
0228 00-5/6 blank