TM 9-2350-256-20-2
0258 00
UNIT MAINTENANCE
RECOVERY VEHICLE, FULL TRACKED: MEDIUM, M88A1
FEMALE CABLE CONNECTOR (WITH SLEEVE) REPAIR
INITIAL SETUP:
Tools and Special Tools
Tool kit, electrical (item 166, WP 0488 00)
WARNING
Be certain MASTER switch is OFF when working on electrical system to avoid electrical shock and
burns.
Repair or Replacement
1.
Strip cable (1) insulation equal to depth of terminal (2) well.
2.
Slide shell (3) and sleeve (4) over cable (1).
3.
Insert cable into terminal (2) well and crimp.
4.
Slide shell (3) and sleeve (4) over terminal (2).
END OF WORK PACKAGE
0258 00-1/2 blank