FUEL PUMP REPLACEMENT - LEFT FUEL TANK (Sheet 1 of 9)
PROCEDURE INDEX
PROCEDURE
PAGE
Removal
7-52
Installation
7-57
TOOLS:
1/4 in. combination box and open end wrench
1/2 in. combination box and open end wrench
1/2 in. socket with 3/8 in. drive
Ratchet with 3/8 in. drive
Diagonal cutting pliers
Torque wrench with 3/8 in. drive (0-200 lb-in) (0-23 N
•
m)
Slip joint pliers
Flat-tip screwdriver
SUPPLIES:
Lockwire (Item 60, Appendix D)
Gasket (10873918)
Lockwasher (MS35333-38) (2 required)
Lockwasher (MS45904-72)
REFERENCE:
TM 9-2350-260-10
PRELIMINARY PROCEDURES:
Isolate left fuel tank (TM 9-2350-260-10)
Drain left fuel tank (page 7-153)
Remove powerplant (page 5-1)
REMOVAL:
1.
Using hands, unplug electrical lead (A) from capacitor and housing assembly (B) located on fuel tank access cover
(C).
Go on to Sheet 2
TA148127
7-52