TM 9-2350-261-10
START ENGINE — Continued
0026 00
29. Remove driver’s power plant access panel (WP 0048 00).
CAUTION
Never try to move the engine disconnect lever when the engine is running. Do not leave engine
disengaged more than 10 minutes while engine is running. Damage to the transfer gearcase
can result.
30. Pull engine disconnect lever out as far as it will go to connect the engine to the rest of the power plant. If the disconnect
lever is hard to move, press the START switch for a moment to turn the engine a little.
WARNING
Engine exhaust gas is deadly poison. Make sure power plant access panels are closed tight
before you start engine.
31.
Install driver’s power plant access panel (WP 0048 00).
0026 00-13