TM 9-2350-261-10
OPERATE NBC KIT
0068 00
THIS WORK PACKAGE COVERS:
Turn NBC Kit On In Ambulance With Litter Kit (page 0068 00-1).
Turn NBC Kit Off In Ambulance With Litter Kit (page 0068 00-2).
Turn NBC Kit On In Carrier Without Litter Kit (page 0068 00-3).
Turn NBC Kit Off In Carrier Without Litter Kit (page 0068 00-5).
INITIAL SETUP:
Maintenance Level
Operator
Personnel Required
Soldier
Equipment Condition
NBC kit installed
TURN NBC KIT ON IN AMBULANCE WITH LITTER KIT
WARNING
Breathing excessive carbon monoxide gas can kill you. Keep fresh air flow. NBC kit and M42
protective mask will not protect you from carbon monoxide gas nor provide oxygen.
1.
Remove spring clip from air intake openings on air purifier.
NOTE
Air purifier switches are located in various places, such as the instrument panel, transverse
beam, near driver’s seat, and in the rear compartment.
2.
Turn AIR PURIFIER SWITCH ON.
006800-1