TM-9-2350-261-10

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

OPERATOR'S MANUAL

  TM-9-2350-261-10 - Page 397 of 761

TM 9-2350-261-10
OPERATE NBC KIT — Continued
0068 00
2.
Turn AIR PURIFIER SWITCH OFF.
3.
Stow hoses connected to Y connectors out of the way.
4.
Install spring clip over air intake openings on the air purifier.
5.
Clean air purifier housing with a clean cloth as soon as possible after operation.
TURN NBC KIT ON IN CARRIER WITHOUT LITTER KIT
WARNING
Breathing excessive carbon monoxide gas can kill you. Keep fresh air flow. NBC kit and M42
protective mask will not protect you from carbon monoxide gas nor provide oxygen.
1.
All crew members must put on their M42 protective masks. Adjust facepieces.
006800-3


Back to Top