TM 9-2350-261-10
TROUBLESHOOTING TABLE — Continued
0074 00
INITIAL SETUP:
Maintenance Level
Operator
NBC KIT
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
INSUFFICIENT AIR FLOW
AT ALL STATIONS.
1
. Checktoseeifspringclipisdownoverair
intake openings on air purifier.
Raise spring clip from air intake
openings on air purifier (NBC
Kit) (WP 0068 00).
2.
Check to see if air hoses are kinked or
pinched.
Straighten or replace air hoses
(WP 0068 00).
3.
Check to see if there are any loose hose
connections.
Tighten loose connections
(WP 0068 00).
2.
AIR FLOW TOO HIGH AT
ALL STATIONS.
1.
Check to see if air purifier is out of
adjustment.
If air purifier is out of adjustment,
notify unit maintenance.
3.
GAS PARTICULATE
FILTER WILL NOT
OPERATE WHEN SWITCH
IS IN ON POSITION.
1.
Check to see if AIR PURIFIER SWITCH is
in OFF position.
Turn AIR PURIFIER SWITCH
ON (WP 0068 00).
2.
Check to see if ground wire is loose or
missing.
Notify unit maintenance of loose
or missing ground wire.
3.
Check to see if electrical cable assemblies
are loose or missing.
Notify unit maintenance of loose
or missing cables.
0074 00-23/24 blank