TM-9-2350-261-10

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

OPERATOR'S MANUAL

  TM-9-2350-261-10 - Page 442 of 761

TM 9-2350-261-10
TROUBLESHOOTING TABLE — Continued
0074 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
Check for burnt-out fluorescent lamp (lamp
will be gray/black).
Replace lamp as described in TM
10-5410-229-13&P.
Record faulty items on DA Form
2404 and notify unit maintenance.
6.
TENT (COVERED
EXTENSION) LIGHTS
FAIL TO COME ON.
1.
Check to see if MASTER SWITCH is in
OFF position.
Turn MASTER SWITCH to ON
(WP 0026 00).
2.
Check for loose connection of light cord at
receptacle on rear of carrier (M577A2 only).
Tighten connector.
3.
Check for faulty bulbs or loose or faulty
switches or electrical leads (M577A2 only).
Connect disconnected leads.
4.
See TM 10-5410-229-13&P for
troubleshooting tent light set (M1068
only).
Record faulty items on DA Form
2404 and notify unit maintenance.
7.
COMMANDER’S
PLATFORM DOES NOT
POSITION RIGHT.
1.
Check for bent handle, broken spring, or
damaged pin (WP 0023 00).
If any item is damaged, record it
on DA Form 2404 and notify unit
maintenance.
8.
COMMANDER’S
PLATFORM CANNOT
BE STOWED.
1.
Check for faulty latch or spring
(WP 0023 00).
If platform is faulty, record it on
DA Form 2404 and notify unit
maintenance.
9.
SEE TM 10-5410-229-13&P
TO TROUBLESHOOT
MCPS.
0074 00-26


Back to Top