TM-9-2350-261-10

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

OPERATOR'S MANUAL

  TM-9-2350-261-10 - Page 474 of 761

TM 9-2350-261-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued
0075 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
NOTE
On all carriers except M1068, portable
fire extinguisher is located against
curbside rear plate.
On M1068, portable fire extinguisher
is located against curbside wall next to
the map board.
NOTE
Manually lower ramp before
proceeding with PMCS.
a.
Check portable fire extinguisher control
seal. Make sure seal or locking wire is
not broken. Report broken seal to unit
maintenance.
Fire
extinguisher
missing. Seal
or lockwire
missing or
broken.
b.
Check fire extinguisher for security of
mounting hardware and missing hardware.
c.
Check for full charge.
Pressure gauge
indicates
discharge or
seal is broken.
Extinguisher
feels light or
seal is broken,
if no gauge.
0075 00-26


Back to Top