PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued
0075 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
a.
Turn MASTER SWITCH to ON, check air
box heater as follows:
1)
Pull out fuel shutoff control. Press
START switch.
2)
Turn AIR BOX HEATER switch to
ON.
3)
Look for puffs of black smoke from
engine exhaust. If you see smoke, the
heater is OK. Notify unit maintenance
if no smoke appears.
b.
Check binding and sticking of throttle
linkage by depressing and releasing the
accelerator pedal.
Linkage
binding and/or
sticking.
0075 00-29