TM 9-2350-261-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued
0075 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
28
During
Personnel Heater
(Electronic
Equipment Heater
M577A2)
DRIVER
WARNING
Do not operate personnel heater if any
fuel leak is found in heater or in fuel
lines.
a.
Check operation of electronic equipment
heater.
b.
Check exhaust and intake ports for
blockage.
c.
Check air outlet elbow for blockage.
d.
Check for leaks in fuel lines.
Any Class III
fuel leaks.
0075 00-45