PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued
0075 00
Table 5. Preventive Maintenance Checks and Services for Model M113A2 FOV, After
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
36
After
Neutral Start
Switch
DRIVER
NOTE
“After” PREVENTIVE
MAINTENANCE begins the moment
the carrier engine shuts off after
mission mode is completed.
a.
Check for proper operation of neutral start
switch. Engine should only start with range
selector in N range.
Switch
missing.
Engine can
be started in
any forward or
reverse range.
b.
Check range selector mounting screws. If
screws are loose or missing, report it to unit
maintenance.
Mounting
screws loose
or missing.
37
After
Engine Shutdown
DRIVER
WARNING
Hot parts can burn you. Let hot parts
cool before you start work.
a.
Stop engine (WP 0029 00).
Engine won’t
shut down.
b.
Check engine for proper shutdown.
1)
Pull out hand throttle and run engine
at 800 to 1000 RPM until normal idle
temperature of 160 to 185F(71
to 85 C) is reached as indicated by
temperature gauge.